In forceEnergy & Carbon
Passivhaus Classic
Fabric-first, verified low-energy buildings
A voluntary certification standard for very low-energy buildings, based on a fabric-first approach and verified performance criteria.
Also known as: Passive House, Passivhaus, PHPP
Key requirements
- Space heating demand of no more than 15 kWh/m² per year.
- Primary energy demand of no more than 60 kWh/m² per year.
- Airtightness of no more than 0.6 air changes per hour at 50 Pa.
- Thermal comfort and overheating criteria are also assessed.
- Certification requires verification by an accredited Passivhaus certifier.
Performance at a glance
- Heating demand
- ≤ 15 kWh/m²/yr
- Primary energy
- ≤ 60 kWh/m²/yr
- Airtightness
- ≤ 0.6 ACH @ 50 Pa
Applies to
New and retrofit buildings seeking Passivhaus certification.